Utah Code § 15A-4-206

Amendments to IRC applicable to Park City Corporation or Park City Fire District
Open in Lexace · Ask the AI about this section
(1) The following amendment is adopted as an amendment to the IRC for the Park City
Corporation, Appendix P, of the 2006 IRC is adopted.
(2) The following amendments are adopted as amendments to the IRC for Park City Corporation
and Park City Fire District:
(a) IRC, Section R905.7, is deleted and replaced with the following: "R905.7 Wood shingles. The
installation of wood shingles shall comply with the provisions of this section.
Wood roof covering is prohibited in areas with a combined rating of more than 11 using the
following tables with a score of 9 for weather factors.
TABLE
WILDFIRE HAZARD SEVERITY SCALE
RATING SLOPE VEGETATION
1 less than or equal to 10% Pinion-juniper
2 10.1 - 20% Grass-sagebrush
3 greater than 20% Mountain brush or softwoods
PROHIBITION/EXEMPTION TABLE
RATING WOOD ROOF PROHIBITION
less than or equal to 11 wood roofs are allowed
greater than or equal to 12 wood roofs are prohibited"
(b) IRC, Section R905.8, is deleted and replaced with the following: "R905.8 Wood Shakes.
The installation of wood shakes shall comply with the provisions of this section. Wood roof
covering is prohibited in areas with a combined rating of more than 11 using the following
tables with a score of 9 for weather factors.
TABLE
WILDFIRE HAZARD SEVERITY SCALE
RATING SLOPE VEGETATION
1 less than or equal to 10% Pinion-juniper
2 10.1 - 20% Grass-sagebrush
3 greater than 20% Mountain brush or softwoods
PROHIBITION/EXEMPTION TABLE
RATING WOOD ROOF PROHIBITION
less than or equal to 11 wood roofs are allowed
greater than or equal to 12 wood roofs are prohibited"
(c) Appendix K is adopted.

‹ Prev All Utah sections Next ›


Lexace provides legal information, not legal advice, and no attorney–client relationship is created. Statute text is provided for general information and may not reflect the most recent amendments; verify against the official state code.