Utah Code § 15A-3-901

General provisions
Open in Lexace · Ask the AI about this section
Mobile homes built before June 15, 1976, that are subject to relocation, building alteration,
remodeling, or rehabilitation shall comply with the following:
(1) Related to exits and egress windows:
(a) Egress windows. The home has at least one egress window in each bedroom, or a window
that meets the minimum specifications of the United States Department of Housing and Urban
Development's (HUD) Manufactured Homes Construction and Safety Standards (MHCSS)
program as set forth in 24 C.F.R. Parts 3280 and 3282, MHCSS 3280.106 and 3280.404 for
manufactured homes. These standards require the window to be at least 22 inches in the
horizontal or vertical position in its least dimension and at least five square feet in area. The
bottom of the window opening shall be no more than 36 inches above the floor, and the locks
and latches and any window screen or storm window devices that need to be operated to
permit exiting shall not be located more than 54 inches above the finished floor.
(b) Exits. The home is required to have two exterior exit doors, located remotely from each other,
as required in MHCSS 3280.105. This standard requires that a single-section home have the
doors no less than 12 feet, center-to-center, from each other, and a multisection home have
the doors no less than 20 feet, center-to-center, from each other, when measured in a straight
line, regardless of the length of the path of travel between the doors. One of the required exit
doors must be accessible from the doorway of each bedroom and no more than 35 feet away
from any bedroom doorway. An exterior swing door shall have a 28-inch-wide by 74-inch-
high clear opening and sliding glass doors shall have a 28-inch-wide by 72-inch-high clear
opening. Each exterior door other than screen/storm doors shall have a key-operated lock
that has a passage latch; locks shall not require the use of a key or special tool for operation
from the inside of the home.
(2) Related to flame spread:
(a) Walls, ceilings, and doors. Walls and ceilings adjacent to or enclosing a furnace or water
heater shall have an interior finish with a flame-spread rating not exceeding 25. Sealants and
other trim materials two inches or less in width used to finish adjacent surfaces within these
spaces are exempt from this provision, provided all joints are supported by framing members
or materials with a flame spread rating of 25 or less. Combustible doors providing interior or
exterior access to furnace and water heater spaces shall be covered with materials of limited
combustibility (i.e., 5/16-inch gypsum board, etc.), with the surface allowed to be interrupted
for louvers ventilating the space. However, the louvers shall not be of materials of greater
combustibility than the door itself (i.e., plastic louvers on a wooden door). Reference MHCSS
3280.203.
(b) Exposed interior finishes. Exposed interior finishes adjacent to the cooking range (surfaces
include vertical surfaces between the range top and overhead cabinets, the ceiling, or
both) shall have a flame-spread rating not exceeding 50, as required by MHCSS 3280.203.
Backsplashes not exceeding six inches in height are exempted. Ranges shall have a vertical
clearance above the cooking top of not less than 24 inches to the bottom of combustible
cabinets, as required by MHCSS 3280.204(e).
(3) Related to smoke detectors:
(a) Location. A smoke detector shall be installed on any ceiling or wall in the hallway or space
communicating with each bedroom area between the living area and the first bedroom door,
unless a door separates the living area from that bedroom area, in which case the detector
shall be installed on the living-area side, as close to the door as practicable, as required
by MHCSS 3280.208. Homes with bedroom areas separated by any one or combination
of common-use areas such as a kitchen, dining room, living room, or family room (but not
a bathroom or utility room) shall be required to have one detector for each bedroom area.

When located in the hallways, the detector shall be between the return air intake and the
living areas.
(b) Switches and electrical connections. Smoke detectors shall have no switches in the circuit
to the detector between the overcurrent protection device protecting the branch circuit and
the detector. The detector shall be attached to an electrical outlet box and connected by a
permanent wiring method to a general electrical circuit. The detector shall not be placed on
the same branch circuit or any circuit protected by a ground-fault circuit interrupter.
(4) Related to solid-fuel-burning stoves/fireplaces:
(a) Solid-fuel-burning fireplaces and fireplace stoves. Solid-fuel-burning, factory-built fireplaces
and fireplace stoves may be used in manufactured homes, provided that they are listed for
use in manufactured homes and installed according to their listing/manufacturer's instructions
and the minimum requirements of MHCSS 3280.709(g).
(b) Equipment. A solid-fuel-burning fireplace or fireplace stove shall be equipped with an integral
door or shutters designed to close the fire chamber opening and shall include complete
means for venting through the roof, a combustion air inlet, a hearth extension, and means to
securely attach the unit to the manufactured home structure.
(i) Chimney. A listed, factory-built chimney designed to be attached directly to the fireplace/
fireplace stove and equipped with, in accordance with the listing, a termination device and
spark arrester shall be required. The chimney shall extend at least three feet above the part
of the roof through which it passes and at least two feet above the highest elevation of any
part of the manufactured home that is within 10 feet of the chimney.
(ii) Air-intake assembly and combustion-air inlet. An air-intake assembly shall be installed in
accordance with the terms of listings and the manufacturer's instruction. A combustion-
air inlet shall conduct the air directly into the fire chamber and shall be designed to prevent
material from the hearth from dropping on the area beneath the manufactured home.
(iii) Hearth. The hearth extension shall be of noncombustible material that is a minimum of 3/8-
inch thick and shall extend a minimum of 16 inches in front and eight inches beyond each
side of the fireplace/fireplace stove opening. The hearth shall also extend over the entire
surface beneath a fireplace stove and beneath an elevated and overhanging fireplace.
(5) Related to electrical wiring systems:
(a) Testing. All electrical systems shall be tested for continuity, in accordance with MHCSS
3280.810, to ensure that metallic parts are properly bonded; tested for operation, to
demonstrate that all equipment is connected and in working order; and given a polarity check,
to determine that connections are proper.
(b) 5.2 Protection. The electrical system shall be properly protected for the required amperage
load. If the unit wiring employs aluminum conductors, all receptacles and switches rated at
20 amperes or less that are directly connected to the aluminum conductors shall be marked
CO/ALA. Exterior receptacles, other than heat tape receptacles, shall be of the ground-fault
circuit interrupter (GFCI) type. Conductors of dissimilar metals (copper/aluminum or copper-
clad aluminum) must be connected in accordance with NEC, Section 110-14.
(6) Related to replacement furnaces and water heaters:
(a) Listing. Replacement furnaces or water heaters shall be listed for use in a manufactured
home. Vents, roof jacks, and chimneys necessary for the installation shall be listed for use
with the furnace or water heater.
(b) Securement and accessibility. The furnace and water heater shall be secured in place to
avoid displacement. Every furnace and water heater shall be accessible for servicing, for
replacement, or both as required by MHCSS 3280.709(a).

(c) Installation. Furnaces and water heaters shall be installed to provide complete separation of
the combustion system from the interior atmosphere of the manufactured home, as required
by MHCSS.
(i) Separation. The required separation may be achieved by the installation of a direct-vent
system (sealed combustion system) furnace or water heater or the installation of furnace
and water heater venting and combustion systems from the interior atmosphere of the
home. There shall be no doors, grills, removable access panels, or other openings into the
enclosure from the inside of the manufactured home. All openings for ducts, piping, wiring,
etc., shall be sealed.
(ii) Water heater. The floor area in the area of the water heater shall be free from damage from
moisture to ensure that the floor will support the weight of the water heater.

‹ Prev All Utah sections Next ›