Sec. 11. (a) Subject to subsection (c), and except as otherwise allowed by IC 36-7-4-1109 , a project owner may not install or locate one (1) or more wind power devices in a unit unless the project owner demonstrates to the permit authority that with respect to each wind power device that the project owner seeks to install or locate in the unit: (1) the project owner has used shadow flicker computer modeling to estimate the amount of shadow flicker anticipated to be caused by the wind power device; and (2) the wind power device has been designed such that industry standard computer modeling indicates that any dwelling on a nonparticipating property within the unit will not experience more than thirty (30) hours per year of shadow flicker under planned operating conditions for the wind power device. (b) After a project owner installs or locates a wind power device in a unit, the project owner shall work with the owner of any affected dwelling on a nonparticipating property to mitigate the effects of shadow flicker to the extent reasonably practicable. (c) The requirement set forth in subsection (a)(2) may be waived with respect to any one (1) wind power device, subject to the written consent of the owner of each affected nonparticipating property.
‹ Prev All Indiana sections Next ›
Lexace provides legal information, not legal advice, and no attorney–client relationship is created. Statute text is provided for general information and may not reflect the most recent amendments; verify against the official state code.