Any building or portion thereof, regardless of zoning designation or approved uses of the building, including any dwelling unit, guestroom or suite of rooms, or the premises on which the same is located, in which there exists any of the following listed conditions to an extent that endangers the life, limb, health, property, safety, or welfare of the occupants of the building, nearby residents, or the public shall be deemed and hereby is declared to be a substandard building: (a) Inadequate sanitation shall include, but not be limited to, the following: (1) Lack of, or improper water closet, lavatory, or bathtub or shower in a dwelling unit. (2) Lack of, or improper water closets, lavatories, and bathtubs or showers per number of guests in a hotel. (3) Lack of, or improper kitchen sink. (4) Lack of hot and cold running water to plumbing fixtures in a hotel. (5) Lack of hot and cold running water to plumbing fixtures in a dwelling unit. (6) Lack of adequate heating. (7) Lack of, or improper operation of required ventilating equipment. (8) Lack of minimum amounts of natural light and ventilation required by this code. (9) Room and space dimensions less than required by this code. (10) Lack of required electrical lighting. (11) Dampness of habitable rooms. (12) Infestation of insects, vermin, or rodents as determined by a health officer or, if an agreement does not exist with an agency that has a health officer, the infestation can be determined by a code enforcement officer, as defined in Section 829.5 of the Penal Code, upon successful completion of a course of study in the appropriate subject matter as determined by the local jurisdiction. (13) Visible mold growth, as determined by a health officer or a code enforcement officer, as defined in Section 829.5 of the Penal Code, excluding the presence of mold that is minor and found on surfaces that can accumulate moisture as part of their properly functioning and intended use. (14) General dilapidation or improper maintenance. (15) Lack of connection to required sewage disposal system. (16) Lack of adequate garbage and rubbish storage and removal facilities, as determined by a health officer or, if an agreement does not exist with an agency that has a health officer, the lack of adequate garbage and rubbish removal facilities can be determined by a code enforcement officer as defined in Section 829.5 of the Penal Code. (b) Structural hazards shall include, but not be limited to, the following: (1) Deteriorated or inadequate foundations. (2) Defective or deteriorated flooring or floor supports. (3) Flooring or floor supports of insufficient size to carry imposed loads with safety. (4) Members of walls, partitions, or other vertical supports that split, lean, list, or buckle due to defective material or deterioration. (5) Members of walls, partitions, or other vertical supports that are of insufficient size to carry imposed loads with safety. (6) Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that sag, split, or buckle due to defective material or deterioration. (7) Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that are of insufficient size to carry imposed loads with safety. (8) Fireplaces or chimneys that list, bulge, or settle due to defective material or deterioration. (9) Fireplaces or chimneys that are of insufficient size or strength to carry imposed loads with safety. (c) Any nuisance. (d) All wiring, except that which conformed with all applicable laws in effect at the time of installation if it is currently in good and safe condition and working properly. (e) All plumbing, except plumbing that conformed with all applicable laws in effect at the time of installation and has been maintained in good condition, or that may not have conformed with all applicable laws in effect at the time of installation but is currently in good and safe condition and working properly, and that is free of cross connection
‹ Prev All California sections Next ›
Lexace provides legal information, not legal advice, and no attorney–client relationship is created. Statute text is provided for general information and may not reflect the most recent amendments; verify against the official state code.